Key Features
Autoranging output: more voltage and current combinations in one power supply
Built-in waveform function for battery testing
LAN, USB, LXI, CAN, GPIB and Web Server
Returns up to 95% of consumed energy back to the grid without disruptions
Stackable parallel connections up to 16 units
Smooth transition between sourcing and sinking current
Control your instruments for free with the PathWave BenchVue Basic app at www.keysight.com/find/BVBasic
Model Comparison
|
Model
|
Power Output
|
DC output rating
|
Ripple & Noise
|
Voltage
|
Current
|
Transient response
|
|
RP5913A
|
2000 W | 80 V, 40 A | ≤ 200 mVp-p | 0.03 + 24 mV | 0.1 + 40 mA | ≤1 ms |
|
RP5915A
|
500 V, 12 A | ≤ 1500 mVp-p | 0.03 + 150 mV | 0.1 + 12 mA | ||
|
RP5916A
|
800 V, 8 A | ≤ 2400 mVp-p | 0.03 + 240 mV | 0.1 + 8 mA | ||
|
RP5923A
|
4000 W | 80 V, 80 A | ≤ 200 mVp-p | 0.03 + 24 mV | 0.1 + 80 mA | |
|
RP5925A
|
500 V, 24 A | ≤ 1000 mVp-p | 0.03 + 150 mV | 0.1 + 24 mA | ||
|
RP5926A
|
800 V, 16 A | ≤ 1600 mVp-p | 0.03 + 240 mV | 0.1 + 16 mA | ||
|
RP5933A
|
6000 W | 80 V, 120 A | ≤ 200 mVp-p | 0.03 + 24 mV | 0.1 + 120 mA | |
|
RP5935A
|
500 V, 36 A | ≤ 500 mVp-p | 0.03 + 150 mV | 0.1 + 36 mA | ||
|
RP5936A
|
800 V, 240 A | ≤ 1000 mVp-p | 0.03 + 240 mV | 0.1 + 24 mA | ||
|
RP5943A
|
12000 W | 80 V, 240 A | ≤200 mVp-p | 0.03 + 24 mV | 0.1 + 240 mA | |
|
RP5945A
|
500 V, 72 A | ≤ 500 mVp-p | 0.03 + 150 mV | 0.1 + 72 mA | ||
|
RP5946A
|
800 V, 48 A | ≤ 1000 mVp-p | 0.03 + 240 mV | 0.1 + 48 mA |