Key Features
Powerful marker functions: including frequency counter, band power, marker demodulation and noise marker
Uo to 7 GHz tracking generator with built-in VSWR bridge, covering return loss, VSWR, insertion loss and DTF*
AM/FM, ASK/FSK demodulation analysis
Spectrogram recording and playback makes noise detection and interference hunting easy and intuitive
* VSWR bridge only available on N9321C/22C
Key Specifications
Up to 20 GHz frequency range
Typical –152 dBm displayed average noise level (with preamp on), 10 Hz RBW
90 dBc/Hz phase noise
10 Hz to 3 MHz resolution bandwidth
± 0.6 dB total amplitude accuracy
Qualify
Need spectrum monitoring and interference analysis? Sell option N932xC-MNT and SCN.
Need USB power meter support? Sell option PWM, or PWP.
Need test low-level signals? Sell option P04/P07/P13/P20
Need stimulus/response measurement? Sell option TG7 (tracking generator).
Included Accessories
N-BNC adapter, BNC cable
Related Products
X-Series signal generators
U2000, U2020 X-Series USB power sensors
Y1800A RF training kit
Model Comparison
|
|
N9321C |
N9322C |
N9323C |
N9324C |
|
Frequency range |
9 kHz to 4 GHz |
9 kHz to 7 GHz |
1 MHz to 13.6 GHz |
1 MHz to 20 GHz |
|
Reference aging rate |
± 1 ppm, ± 0.1 ppm (w/Opt. PFR) |
± 1 ppm, ± 0.1 ppm (w/Opt. PFR) |
± 1 ppm, ± 0.1 ppm (w/Opt. PFR) |
± 1 ppm, ± 0.1 ppm (w/Opt. PFR) |
|
Amplitude accuracy |
± 0.6 dB |
± 0.6 dB |
± 0.7 dB |
± 0.7 dB |
|
Displayed average noise level, 1 GHz |
–149 dBm |
–149 dBm |
–140 dBm |
–140 dBm |
|
Resolution bandwidth |
10 MHz to 3 MHz |
10 MHz to 3 MHz |
10 MHz to 3 MHz |
10 MHz to 3 MHz |
|
Third-Order Intercept (TOI) |
+15 dBm |
+15 dBm |
+15 dBm |
+15 dBm |
|
Standard attenuator |
50 dB, in 1 dB steps |
50 dB, in 1 dB steps |
50 dB, in 5 dB steps |
50 dB, in 5 dB steps |
|
Phase noise, 1 MHz offset |
–121 dBc/Hz |
–121 dBc/Hz |
–119 dBc/Hz |
–119 dBc/Hz |
|
Data Sheet |
Optional Accessories
|
N9311X Series |
Antenna, near-field probes |
|
BV9001B |
PathWave BenchVue Spectrum Analyzer Control & Automation app |
|
R-50C-011-3 |
3 Year Calibration Plan |
|
R-50C-011-5 |
5 Year Calibration Plan |
|
R-51B-001-5Z |
5 Year Warranty Plan |

Configuration Guide: 3121-1290
Robust measurement features enable your flexibility in RF test
One-button PowerSuite measurements include CHP, ACPR, OBW, and SEM
Window Limit enables fast Pass/Fail test against frequency and amplitude limits simultaneously
CISPR-16 compliant EMI filter and quasi-peak detector make EMI troubleshooting test easy
Tough to beat performance, efficiency and simplicity
Features like proven testing efficiency, best-in-class usability, and the flexibility to adapt to new requirements are just a few of the reasons using the N932xC means you can rely on results.