Need to measure temperature?
Sell any DAQM900A/901A/902A modules.
They differ in channel scanning speed and max power input.
Need higher ch scan rate?
Sell DAQM900A module at 450 ch/s or introduce them to the 34980A.
Need more than 60 channels?
Sell the DAQM908A, add a second DAQ970A to run simultaneously or the 34980A (up to 560 channels)
Need a higher number of channels?
DAQ970A or DAQ973A and DAQM908A.
Need to easily view, capture, export data and screen images?
Download free BenchVue Basic app: www.keysight.com/find/BVBasic
Need a 34972A replacement?
Sell DAQ970A.
What kind of termination does the customer need? Screw post? Solder terminal?
Don’t forget the terminal block when you sell a module. Example the 34922T is needed to connect to the 34922A mux.
Need ATE switching?
Sell matrix, mux, RF or GP plug-ins.
Need digital I/O or analog output?
Sell 34950A (digital I/O) or 34952A (both digital I/O and analog output).
Need rackmount kits?
Sell the Y1130B Rackmount Kit. Can mount forward or reverse in a standard 19" rack.
Need advanced data logging software?
Download the free BenchVue Basic app from www.keysight.com/find/BVBasic
Use the answers to choose the most suitable model from the table below.
| How many signals will you connect at one time? | ||
|
60 2-wire ch |
Up to 120 1-wire mux, 60 2-wire mux or 96 matrix cross points with DAQ970A (USB, LAN) or DAQ973A (USB, LAN, GPIB). |
|
|
560 2-wire ch and 26.5 GHz frequency |
Up to 640 1-wire mux, 560 2-wire mux or 2048 2-wire matrix cross-points with 34980A (USB, LAN, GPIB (LXI). |
|
| What types of measurements will you need? | ||
| Variety of electrical and mechanical signals | All models perform the temperature measurements common in data-logging applications. Other common data acquisition measurements include voltage, current, resistance, frequency and event count. Use the DAQM900A solid state mux model for faster switching time and the new DAQM909A Digitizer for characterization of electromechanical devices. | |
| What kind of switching configuration will you need? | ||
| Multiplexer | A multiplexer configuration is used for signal switching to a single measuring instrument. One signal is connected at a time to the measuring device, and the input is disconnected before a new input is connected. | |
| Matrix | A matrix configuration offers more switching flexibility by connecting multiple inputs, such as signal sources, to multiple outputs, such as test inputs. | |
| Multifunction | Multifunction cards provide a mix of digital and analog input and output. | |
| RF & microwave | Available for the 34980A in a variety of configurations. | |
| Model Number | ➤ Why buy? 1 Min Sell | No. of Slots | No. of Module Types | 61/2 Digit DMM | Max mux Ch (2-wire) | Max Matrix Cross Points | Removable Terminal Blocks | Max Frequency | Scan Channels/Sec |
|---|---|---|---|---|---|---|---|---|---|
| DAQ970A | New measurement types and improved accuracy over legacy 34970A | 3 | 10 | x | 60 | 96 | 2 GHz | 450 | |
| DAQ973A | New measurement types and improved accuracy over legacy 34970A | 3 | 10 | x | 60 | 96 | 2 GHz | 450 | |
| 34980A | High-performance platform | 8 | 21 | x | 560 | 2048 | x | 26.5 GHz | 1000 |